[. . . ] (rated 100-120 Vac) Only FCC Declaration of Conformity We, the Responsible Party EIZO NANAO TECHNOLOGIES INC. 5710 Warland Drive, Cypress, CA 90630 Phone: (562) 431-5011 Trade name: EIZO Model: FlexScan L363T/L353T declare that the product is in conformity with Part 15 of the FCC Rules. Operation of this product is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. [. . . ] The correct displayed position of the monitor is decided because the number and the position of the pixels are fixed. The "Position" adjustment moves the image to the correct position. Select <Position> and adjust the position by using the Up, Down, Right and Left Buttons. If vertical bars of distortion appear after finishing the <Position> adjustment, return to <Clock> adjustment and repeat the previously explained adjustment procedure. Clock Phase Position 4. To adjust the output signal range (Dynamic Range) of the signal. Use the <Range Adjustment> (p. 42) of <Screen> menu. This controls the level of output signal range to display the whole color gradation (256 colors). [Procedure] Press the Auto Adjustment Button on the control panel while displaying the <Range Adjustment> menu to automatically adjust the range. The screen blanks for a moment, and adjusts the color range to display the whole color gradation of the current output signal. 5. To smooth the blurred texts of the enlarged screen of the lower resolutions. Switch the <Smoothing> setting. <Smoothing> is clear-cut the letters or lines. Select <Smoothing> in the screen menu and select the suitable level from 1 ~ 5. NOTE · The "Smoothing" is disabled in the resolution 1024 x 768. · Since the displayed image is enlarged, the blurred texts may not be necessarily lost completely. 4. ADJUSTMENT 23 English 6. To Set the Brightness of the screen. Use the <Brightness> adjustment. The brightness of the entire screen is controlled by changing the brightness of the backlight. Select < Brightness > in the screen menu and adjust by using the Up and Down Buttons. NOTE · Directly pressing the Up and Down Buttons also adjusts the brightness. Press the Enter Button to save and exit the settings after the adjustment. 24 4. Color Adjustment The <Color> menu in the ScreenManager enables to change the color of the screen. By using the <Color Mode>, the adjustment mode can be selected from <Custom mode> (to adjust the color settings according to your preference) and <sRGB> mode. In the analog input, perform the "Range Adjustment" (p. 23) before making the color adjustments. NOTE · Allow the LCD monitor to stabilize for at least 20 minutes before making image adjustments. (Allow the monitor to warm up for at least 20 minutes before making adjustments. ) · Performing the <Reset> of the <Color> menu returns the color settings to the default settings · The values shown in percentages represent the current level within the specific adjustment. (To create an uniform white or black screen, the percentages for each will probably not be the same. ) Adjustment Contents Menu Color Mode Custom sRGB Function Descriptions To set the brightness of the screen To set the color temperature Adjustable range 0 100% 4, 000 10, 000 K in 500 K increments (including 9, 300 K). [. . . ] The customer or the user of the FlexScan L363T-C/L353T-C can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the FlexScan L363T-C/L353T-C as recommended below, according to the maximum output power of the communications equipment. Rated maximum output Separation distance according to frequency of transmitter power of transmitter m 150kHz to 80MHz 80MHz to 800MHz 800MHz to 2. 5GHz W d = 1. 2 P d = 1. 2 P d = 2. 3 P 0. 01 0. 12 0. 12 0. 23 0. 1 0. 38 0. 38 0. 73 1 1. 2 1. 2 2. 3 10 3. 8 3. 8 7. 3 100 12 12 23 For transmitters rated at a maximum output power not listed above, the recommended separation distance "d" in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where "P" is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. [. . . ]